Mobotix T24 User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 9
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
MOBOTIX T24 Integration 6
On the Door’s Local tab, select the AUX input’s “Authorized Access” option.
2.2.2: CRYSTAL SOFTWARE PERMISSION CONFIGURATION
To support the AUX input, while the PowerNet is operating in “Host” mode, a
permission will need to be defined. This is a typical permission within Crystal
Matrix, and the major steps required to accomplish this are:
Assigned the “AUX pseudo-person” to a specific PeopleGroup
Define a “Shift” that covers the timeframe that the T24 will be allowed to
open the door
Define a Permission that includes:
o For that Door
o For that PeopleGroup
o During that Shift
Note:
While the PowerNet is operating in Local/Standalone mode, the PowerNet will
always accept the T24’s request to open the door.
Page view 5
1 2 3 4 5 6 7 8 9

Comments to this Manuals

No comments