2.8.2 Configuring The T24-DoorMaster
Before using the T24-DoorMaster, it is essential to configure the signal output option to
be used (see Section 2.5.2).
Three Options Are Available
Option 1: Power Supply From T24-DoorMaster Battery (Self-Powered)
The door opener is supplied with a pulsed 12 V voltage (max. 10 W) from the battery. This
state is signaled by a green LED in configuration mode. As this is the factory default setting,
no further configuration is required for this connection option.
Option 2: Power Supply From External Power Supply Unit (Internal Relay Function)
The relay integrated into the T24-DoorMaster switches an external voltage that powers the
connected door opener. This is signaled by a red LED in configuration mode. Configuration
is required here (see below).
Option 3: Self-Locking Mediator Door Lock Including UPS Via Battery Pack
A DC control signal is switched to the control input of the Mediator (special door opener
that keeps the door permanently locked). This is signaled by a blue LED in configuration
mode. Configuration is required here (see below).
D$<(?>"-$#$;
P2+*';*#; 7$#2&"'Q
K'+$#'*< #$<*4 (3'1+&"'
!$;&*+"#
LED (blue)
Door opener
and emergency
unlocking
(in the event of
a power failure)