91/148
Network And Power Connection, Additional Cables
© MOBOTIX AG • Security Vision Systems • Made in Germany
2.5.2 Network Cabling For S14 With Patch Cables
1.
Remove housing cover and cable
plugs
: Loosen the Allen screw on
the housing cover of the S14 and
remove it. Push the cable plug
in the camera out of the hous-
ing from the inside to the outside
(red arrow).
2.
Attach the cable ties
: Feed one
of the cable ties supplied through
both slots in the circuit board
underneath the LSA cutting clamp.
3.
Prepare the installation cable
:
Cut the installation cable to
length, feed through the white
single wire plug (5-7mm/0.2 to
0.28in), remove 35mm/1.38in of
insulation and separate into indi-
vidual twisted wire pairs including
15mm/0.6 in sheathing. Wind the
shield mesh around the sheath to
a width of 10mm/0.4in so that it
can be fixed on the contact surface
later using the cable tie.
4.
Secure the cable
: Push the
plug out and insert the installa-
tion cable with single wire plug
(5-7 mm/0.2 to 0.28in) into the
opening intended for the instal-
lation cable. The rubber sleeve
must sit tightly on the installation
cable to prevent the penetration
of moisture. Tighten the cable tie
around the shield mesh to ensure
less tension.
~15mm
~35mm
~20mm
~10mm
Shield meshCable
Wire shield
Ensure that the instal-
lation cable is fed right
into the housing when
the camera is in the right
position so that the cable
plug provides optimal
sealing for the housing
Comments to this Manuals