eventcounter_filter Individual Events yes, no yes
eventcounter_time Counting Period 1 .. 3600 10
eventcounter_event Event Count 1 .. 3600 5
eventcounter_condition Condition more, less more
eventcounter_action Start Action first, every every
54.2.13 Parameters for the settings Section
Enter the following command to see all parameters for this section:
http://<camera ip>/control/control?listsectionsettings
Parameter Name in
Dialog
Possible Values Default
Value(s)
Arming
edactiv Arming enable, disable, close, open enable
edacttimetable Time Table
Profile
(No value), Weekdays_Mo−Fr, Weekend_Sa−So,
Opening_Times, Closing_Times, MyCustomTimes
Stop Actions (SP)
freezeactiv Activate Stop
Actions
off, on off
freezecondition Condition to
Stop
PI, VM, MI, SI, BT, IR, PE, TT, UC, RC, RD, EC UC
freezedelay Time Before
Stop
0 .. 86400 15
Event Dead Time
eventdelay Event Dead
Time
0 .. 3600 5
Action Delay
actiondelay Action Delay 0 .. 3600 0
Ring Buffer
ringbuffer Ring Buffer 1, 0 1
Event Story
histcount Images Before
Event
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 25, 30, 35, 40, 45, 50 1
futcount Images After
Event
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 25, 30, 35, 40, 45, 50 2
storyinterval Image Interval 0 .. 600000 500
story_alertmask Event Selection (String constant) *