26 The Serial Interface
Open the Serial Interface and Modem Setup dialog to select the interface type, its mode and to set the
parameters of the serial interface.
You can use the serial interface either as signal in−/output for controlling external devices (e.g. alarm bell and
light using a relay), for transferring data via a modem or mobile phone or as a web terminal for
controlling/monitoring machines.
Note: This feature is not available for Web models.
26.1 Selecting the Operating Mode
Select how you would like to use the serial interface in the Operating mode drop−down box:
Serial Description
Data The serial interface operates as as terminal or as enhanced signal in−/output
Modem An analog modem or GSM is used with the serial interface.
off The serial interface is deactivated.
Notes:
Depending on the selected operation mode, additional parameters are displayed.
If the serial interface has been deactivated before, it will be available only after rebooting the
camera.
26.2 The Data Operating Mode
In the Data operating mode, you can use the camera as web−based data terminal for controlling, monitoring
and remotely maintaining machines or to control other devices via the enhanced signal in−/output.
Parameter Description
Mode
Terminal and
Logger Mode
The camera can be used for monitoring
and controlling production machines,
heating systems and other devices
equipped with a serial interface.
Note:
The integrated web terminal is only
activated after the camera has been
rebooted.
I/O Mode The three remaining pins are available as
signal in−/output. Open the Signal State
dialog if you would like to configure this
option.
26 The Serial Interface 58