1.6.8 Deactivating the Daily Reboot of the Camera
In its factory state, the MOBOTIX camera will automatically reboot every morning at
3:36 am. In very rare cases, external influences (e.g. radiation in high locations)
can lead to camera malfunctions. The automatic reboot will refresh the camera's
memory and will ensure proper operation without requiring any interaction on the
part of the user.
Open Admin Menu> Time Tasks and deactivate or delete the
Reboot camera
task. This will prevent the camera from rebooting automatically.
1.6.9 ISDN Compatibility Note
This product is compatible with Euro ISDN standard TBR3/TBR 3A1.
Note: MOBOTIX offers special models for the Japanese market that support the
Japanese ISDN standard. For additional information on this topic, see the Japanese
section at www.mobotix.com.
1.6.10 Browser Hints
Current browsers with activated JavaScript (Internet Explorer, Netscape, Mozilla,
Firefox, Safari, Konqueror, Opera, …) can show the camera's live images with their
standard settings. Text-based browsers (e.g. lynx) cannot display the user
interface and are
not
suitable for operating the camera.
Section 4.9,
Browser Settings
, contains more information on browser compatibility.
Chapter 12,
Troubleshooting
, contains more information on how to track and
remove errors when operating the camera.
1.6.11 Safety Notes for Operating MOBOTIX Cameras
Electrical surges can be induced by other electrical appliances, improper wiring,
but also from the outside (e.g. lightning strikes in phone or power lines).
MOBOTIX cameras are protected against small electrical surges by numerous
measures. These measures, however, cannot prevent the camera from being
damaged when stronger electrical surges occur.
Special care should be taken when installing the camera outside of buildings for
protection against lightning, since this also protects the building and the whole
network infrastructure.
MOBOTIX recommends having MOBOTIX cameras installed only by specialists
accustomed to installing network devices and having proper respect for the
pertinent regulations regarding lightning protection and fire prevention as well as
the current technology for preventing damages from electrical surges.
Section 2.10,
Wiring, Fire Prevention, Lightning and Surge Protection
, contains more
information on these topics.
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • [email protected] • 22.11.2006
24/96
D12 Camera Manual Part 1
Deactivating the camera
reboot
Page view 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 99 100

Comments to this Manuals

No comments